The Standard Calculator follows the order of operations
The Standard Calculator on the home page supports addition, subtraction, multiplication, division, and parentheses. Multiplication and division come before addition and subtraction: 2 + 3 × 4 = 14, while (2 + 3) × 4 = 20.
% divides the value immediately before it by 100. For example, 200 × 10% = 20 and 200 + 10% = 200.1. To increase 200 by 10%, enter 200 × (1 + 10%).
Standard Calculator results are rounded to a maximum of 10 decimal places, with unnecessary trailing zeros removed. The “≈” symbol appears when rounding for display changes the value. The default of 2 decimal places and the precision choices described below apply to the Percentage Calculator.
Expressions can contain up to 256 characters. Each number can have up to 15 digits before the decimal point and 10 after it. .5 is treated as 0.5. Use a period for decimals. Correctly grouped thousands commas are accepted: 1,000 + 500 = 1,500. Incorrect grouping such as 12,34 shows an error; commas are never treated as decimal points. Scientific notation and functions are not supported. Multiplication must be explicit: enter 2 × (3 + 4) instead of 2(3 + 4). The absolute value of every intermediate value and result must be no greater than 1050.
Copy the currently displayed result
Use “Copy result” to copy your current result, including labels, units, and any approximation marks. Summary results and displayed result tables are included; worked steps and expandable breakdowns are not. Copying does not add a history entry or send the result to our server.
Changing an input clears the result and disables copying until you calculate again. Changing display precision updates the text available to copy. If your browser blocks automatic copying, use the selectable result text and manual-copy instructions.
Recent calculations stay with your browser tab
All calculators add a summary and result after a successful calculation. The Recent calculations section on the home page keeps the five latest entries, with the newest first. An entry identical to the immediately preceding entry is not added again. Errors, editing inputs, and changing only the displayed decimal places do not add entries.
Selecting a Standard Calculator entry loads its expression into the calculator. New entries from the Loan Payment, Discount, Date Difference, Aspect Ratio, Business Days, and Nth Weekday Calculators and the Recipe Scaler offer “Load inputs” to restore the values and options used. Review the restored inputs and select Calculate (or Scale recipe); opening an entry does not calculate or add another record. Older entries without saved inputs and entries from other calculators open the relevant page with its usual defaults.
Business Days saves the selected mode, start date, weekend schedule, and entered holidays. Count business days also saves the end date and both endpoint choices; Add / subtract business days saves the offset; Business-day date range saves the minimum and maximum. Inputs unused by the selected mode are not saved. Different saved conditions remain separate records even when the result is the same.
History uses sessionStorage in the current tab and survives navigation between pages on the same site and page refreshes. It is not sent to a server or saved in cookies or localStorage. Use “Clear all” on the home page to delete this tab’s history. A browser normally clears it when the tab’s session ends, but restoring or duplicating a tab may restore or copy it.
If session storage is unavailable, calculations still work, but history lasts only on the current page. A notice on the home page explains this limitation. Read our privacy policy for more about browser storage.
Share a calculation's inputs
After a successful calculation, the Loan Payment, Discount, Date Difference, Aspect Ratio, Business Days, and Nth Weekday Calculators and the Recipe Scaler offer “Copy link.” The link contains input values and options, including the selected decimal places for aspect ratios and recipes, optional screen diagonal, recipe ingredient rows, and the Business Days conditions described above. It does not contain a stored result. A recipient reviews the restored inputs and calculates a result under the tool's current rules.
New share links are limited to 2,048 characters for the complete encoded address. This is our sharing limit, not a universal browser limit. Longer inputs show a notice instead of being shortened. The Recipe Scaler also offers “Save inputs file” and “Load inputs file” for full recipe conditions, including up to 20 ingredients. Files must be supported JSON input files no larger than 64 KiB; validation happens before any inputs are replaced. Rejected files leave current inputs unchanged. Changing inputs while a file is being read cancels that restore.
Business Days can retain up to 200 entered holiday dates, including repeated entries. Surrounding spaces and empty lines are removed when saving, and each date is restored on its own line. If the conditions exceed the link limit, “Load inputs” in Recent calculations can still restore the full saved conditions in the same tab using a temporary session-storage copy. Holiday dates are not dropped to make a link fit.
Editing an input or resetting the form clears the previous link control until another successful calculation. Copying a link, loading inputs, and changing only the displayed decimal places do not add history entries. Malformed or unsupported links show a notice; they are not executed as code.
Anyone with a calculation link or input file can read its input values. Shared data is not encrypted or password protected, and clearing your history does not revoke copies you have already shared. See the privacy policy for calculation links and files.
Decimal calculations use a shared engine
The Standard, Percentage, Average, and Discount Calculators and the Unit Converter share a decimal.js engine that processes inputs as decimal strings and uses 60 significant digits for internal calculations. This avoids carrying the binary floating-point representation errors of JavaScript’s default number type, such as those seen in 0.1 + 0.2, into ordinary decimal calculations.
However, a finite number of digits cannot exactly represent a repeating decimal such as 1 ÷ 3. Internal calculation precision and the number of decimal places displayed on screen are different settings. Displayed, rounded values are not reused for intermediate calculations.
Choose decimal places in the Percentage Calculator
Results display 2 decimal places by default. You can choose 0, 2, 4, 6, or 10 decimal places. Trailing zeros are retained to match your choice. Commas separate thousands, and a period marks the decimal point.
Values are rounded to the nearest value at the selected precision. Exact ties are rounded away from zero, for both positive and negative numbers. A negative value that rounds to zero is displayed without a minus sign.
| Calculated value | Displayed value | Rule |
|---|---|---|
| 1.004 | ≈ 1.00 | Round to the nearest value |
| 1.005 | ≈ 1.01 | Round exact ties away from zero |
| −1.005 | ≈ −1.01 | Apply the same rule to negative values |
| 12 | 12.00 | Keep the selected decimal places |
| −0.001 | ≈ 0.00 | Display zero without a minus sign |
The “≈” symbol appears when rounding for display changes the value. Its absence means no additional rounding was needed for display; it does not guarantee infinite precision for every mathematical calculation.
Percentage Calculator input limits
Each input can have up to 15 digits before the decimal point and 10 after it. Positive and negative numbers are accepted, as are correctly placed thousands separators. Unit symbols, expressions, and scientific notation are not accepted.
- Accepted examples:
1234.5,1,234.5,-25 - Not accepted:
12,34,15%,1+2,1e3 - Use the same unit for both values in “What percent?” and “Percentage change”. In “Percentage of a number”, the second input is a percentage (%). Units are not converted automatically.
Invalid calculations show an explanation
Empty inputs and invalid number formats show an error message instead of a result. Division by zero also shows an error, rather than displaying infinity or treating it as a valid numerical result.
- In “What percent?”, the whole cannot be zero.
- In “Percentage change”, a zero original value makes the percentage undefined because the formula divides by that value. Negative original values are not supported: the formula can produce a percentage whose sign is misleading as an increase or decrease. In either case, valid inputs still allow us to show the signed change in value,
new − original, separately from a percentage. For example,0 → 100has a change in value of+100, but no defined percentage change. - Changing an input or calculation mode clears the previous result. Calculate again to get a result for the new inputs.
Fractions keep an exact result
The Fraction Calculator uses integer arithmetic for the numerator and denominator, then reduces the result by their greatest common divisor. The simplified fraction is exact. A mixed number is also shown when there is a whole part and a nonzero fractional part.
Each input accepts up to 15 digits, excluding an optional sign. Numerators can be negative or zero; denominators must be greater than zero. Decimals, commas, exponents, and mixed-number input notation are not supported. Division by a zero fraction shows an error.
Decimal output uses the shared 60-significant-digit decimal engine and defaults to a maximum of 10 decimal places. You can select 0, 2, 4, 6, or 10 places; unnecessary trailing zeros are removed. Exact ties round away from zero. The displayed decimal is compared with the exact fraction to decide whether to show ≈. Changing decimal places does not change the fraction or its calculation steps.
Time durations use whole minutes
The Time Duration Calculator subtracts two clock times, adds 24 hours when Next day is selected, and deducts a break entered in whole minutes. A blank break means zero. The break cannot exceed the elapsed interval.
The maximum interval is 47 hours 59 minutes. Equal start and end times mean zero on the same day or 24 hours on the next day. This calculator does not use actual dates, time zones, or daylight-saving changes, so it measures wall-clock time rather than elapsed time across a clock change.
Hours and minutes are exact at the entered minute precision. Decimal hours are rounded to 2 places using the shared decimal engine, with ≈ when the display is rounded. For example, 80 minutes is exactly 1 hour 20 minutes but approximately 1.33 decimal hours.
Averages use every value in the list
The Average Calculator accepts up to 1,000 numbers in at most 64,000 characters. Each number can have up to 15 digits before the decimal point and 10 after it. In the default one-per-line mode, blank lines are ignored and correctly grouped thousands separators are accepted. In comma-separated mode, every comma separates two values; empty entries show an error, and commas cannot also represent thousands separators.
The arithmetic mean is the sum divided by the count. The median is the middle sorted value, or the mean of the two middle values for an even count. Duplicate values are counted separately. Results default to 2 decimal places, with a choice of 0, 2, 4, 6, or 10. Changing display precision does not change the values used to calculate the statistics.
Unit conversions use documented definitions
The Unit Converter covers length, mass, and absolute temperature. Length uses the international foot and mile, and ounces and pounds are avoirdupois mass units. The calculator page links to the definitions used. It does not convert fluid ounces, currencies, or temperature differences.
Each input accepts up to 15 digits before the decimal point and 10 after it. Temperatures below absolute zero are rejected. Results default to 6 decimal places, with a choice of 0, 2, 4, 6, or 10. The swap button exchanges the selected units while keeping the original input number, then clears the old result. It does not feed a rounded result into a new conversion.
Discounts are applied in a stated order
The Discount Calculator applies the first percentage discount, then an optional additional percentage discount to the reduced price, and finally an optional flat coupon. Each percentage must be between 0 and 100. The original price and coupon must be nonnegative. Each numeric input accepts up to 15 digits before the decimal point and 10 after it.
A blank additional discount or coupon means zero. A blank comparison discount disables comparison; entering 0 compares against the full original price. Coupons cannot reduce the final price below zero, and any unused coupon amount is shown. The combined percentage excludes the flat coupon.
Results are displayed to 2 decimal places using the shared rounding rule, without rounding intermediate prices. Taxes, shipping, currency conversion, and store-specific rounding or coupon rules are excluded. All prices and coupon amounts must use the same currency or unit.
Date differences count calendar days
The Date Difference Calculator uses Gregorian calendar rules for years 0001 through 9999, including dates before the calendar was historically adopted. A leap year is divisible by 4, except century years must also be divisible by 400. Invalid dates and an end date before the start date show an error.
By default, the interval starts on the start date and stops before the end date. Including the end date adds one day. Equal dates therefore give zero days, or one day when the end date is included. Weekdays mean Monday through Friday; weekends mean Saturday and Sunday. Public holidays are not removed.
Results use whole calendar days rather than elapsed hours. Time zones and daylight-saving changes do not affect the count. Weeks are full groups of seven days, with any remaining days shown separately.
Ratios and proportions retain exact answers
The Ratio Calculator accepts nonnegative decimal inputs with up to 15 integer digits and 10 decimal places. Simplification scales both values to integers and divides by their greatest common divisor. One zero term is allowed; a ratio of 0:0 is undefined.
The proportion mode solves A:B = C:X as X = B × C ÷ A. A, B, and C must all be greater than zero so both quotients in A/B = C/X are defined. The result is kept as an exact integer or fraction. Its decimal equivalent defaults to a maximum of 6 places, with 0, 2, 4, 6, or 10 available. Trailing zeros are removed, exact halfway values round away from zero, and ≈ indicates that the displayed decimal differs from the exact fraction.
Tips are rounded once, then split in whole cents
The Tip & Bill Split Calculator is for amounts with two decimal places. The entered bill must be nonnegative, with up to 15 integer digits and 2 decimal places. The tip rate must be between 0 and 100 percent, with up to 10 decimal places. The group size must be a whole number from 1 to 1,000.
The tip is calculated on the entire bill amount entered, then rounded once to the nearest cent with halfway values rounded up. A note identifies any rounding. The payable total is the entered bill plus that rounded tip. Taxes and other charges are not added automatically.
The total is divided in whole cents. If equal shares leave a remainder, that many people pay one cent more than the others. The displayed shares add up exactly to the payable total. This rule differs from rounding each person's share independently.
Unit prices compare equivalent quantities
The Unit Price Calculator compares two total offer prices per kilogram, liter, or item. Total quantity is the amount in one pack multiplied by the number of packs, then converted to the common unit. Prices must be nonnegative and quantities positive. Item counts must be whole numbers; packs must be a whole number from 1 to 1,000.
Price and quantity inputs accept up to 15 integer digits and 10 decimal places. The calculator uses an independent 100-significant-digit decimal configuration and cross multiplication, preserving the comparison products within these limits. It compares original values, even when displayed unit prices match. Unit prices, quantities, and savings percentages display 4 decimal places; equivalent prices display 2, using the shared rounding rule.
The percentage saving uses the higher unit price as its baseline. Both prices may be zero; in that case, the result is a tie with no percentage saving calculated. Weight cannot be compared directly with volume. US and Imperial fluid ounces are distinct, and ounces in the weight category are avoirdupois mass.
Fuel costs are estimates from the inputs you supply
The Fuel Cost Calculator combines distance, fuel consumption, and fuel price using an independent 100-significant-digit decimal configuration. It distinguishes US and Imperial gallons and converts using exact definitions: 1 mile = 1.609344 km, 1 US gallon = 3.785411784 L, and 1 Imperial gallon = 4.54609 L.
Distance and fuel price must be nonnegative; consumption must be positive. These inputs accept up to 15 integer digits and 10 decimal places. A blank number of people means 1; otherwise, it must be a whole number from 1 to 1,000. At zero distance, trip cost is zero and cost per distance is undefined.
Results default to 2 decimal places with 4, 6, and 10 available. A per-person share is an independently rounded estimate, not an allocation guaranteed to add up in cents. Actual consumption, fuel prices, tolls, parking, and other trip costs can differ. No live prices or exchange rates are fetched.
Speed, distance, and time use exact unit ratios
The Speed, Distance & Time Calculator solves speed = distance ÷ time, distance = speed × time, or time = distance ÷ speed. It preserves entered decimals and conversion factors as integer fractions until display rounding. The international mile is exactly 1,609.344 meters.
Speed and distance inputs accept nonnegative numbers with up to 15 integer digits and 10 decimal places. Elapsed hours are whole numbers from 0 to 999,999,999, and minutes and seconds are whole numbers from 0 to 59; blank time components mean zero. Calculating speed requires positive time, and calculating time requires positive speed.
Decimal results default to 6 places, with 0, 2, 4, 6, and 10 available. Hours/minutes/seconds results round to the nearest second, with exact halves rounded up. Rounded or very small positive results are identified. This is an average-speed relationship, not live routing or a prediction of traffic and stops.
Areas use squared length conversions
The Area Calculator covers rectangles, triangles, circles, and trapezoids. Only dimensions for the selected shape are used. All dimensions must be positive, with up to 15 integer digits and 10 decimal places, and share the selected length unit. Triangle and trapezoid heights are perpendicular to their bases; circles use the radius, not the diameter.
Length factors are squared to convert areas. The international foot is exactly 0.3048 meters, an acre is exactly 43,560 square feet, and a hectare is exactly 10,000 square meters. Decimal dimensions and unit factors are retained as exact integer fractions. Circle areas retain an exact coefficient of π and use a separate 120-significant-digit decimal configuration to approximate π for display.
Results default to 6 decimal places, with 0, 2, 4, 6, and 10 available. Exact halfway values round up. Circle results always show ≈; other results show it when display rounding changes the exact value. A positive area that rounds to zero is explained. Changing the result unit or precision uses the original area; changing the dimension unit keeps the entered numbers and clears the old result.
Electricity estimates use your entered rate and usage
The Electricity Cost Calculator multiplies power in kilowatts by device count and daily hours to find daily energy in kWh, then multiplies by days and the entered price per kWh. Watts are divided by exactly 1,000 to obtain kilowatts. No live tariff, currency conversion, fixed fee, tax, tiered pricing, or time-of-use rate is added.
Power and price may be zero or positive, with up to 15 integer digits and 10 decimal places. Daily hours range from 0 to 24; days must be a whole number from 1 to 366, and device count a whole number from 1 to 1,000. Devices share the same entered power and operating hours. All fields are required.
A separate 100-significant-digit decimal configuration preserves products within these input limits. Results default to 2 decimal places, with 4, 6, and 10 available, and exact halfway values round up. No intermediate cost is rounded. The 30-day and 365-day references assume the same daily usage throughout; they are separate from the selected period. Actual energy use may differ because of cycling, variable power, or standby use.
Data transfers distinguish bits, bytes, and binary units
The Data Transfer Calculator estimates time as total bits divided by effective bits per second. One byte is 8 bits. KB, MB, GB, and TB use powers of 1,000 bytes; KiB, MiB, GiB, and TiB use powers of 1,024 bytes. Lowercase b in kbps, Mbps, and Gbps means bits; uppercase B in MB/s and MiB/s means bytes.
File size must be nonnegative, bandwidth positive, and efficiency greater than 0 and no more than 100 percent. Inputs accept up to 15 integer digits and 10 decimal places. Efficiency defaults to 100 percent and represents the fraction of entered bandwidth used as effective throughput. No fixed protocol overhead is assumed, and the calculator does not measure your connection.
Transfer time remains the default calculation. Optional average rate divides total bits by positive elapsed seconds, with no further efficiency adjustment. Optional target-time planning divides total bits by positive target seconds to find required effective throughput, then divides by efficiency/100 to find the required stated rate. Time inputs can use seconds, minutes, hours, or 24-hour days. Zero data gives a zero rate, but time and any active efficiency input must still be valid.
Integer fractions preserve unit conversions and calculations exactly until display. The main duration uses 24-hour days and rounds to the nearest second, with halves rounded up. Decimal values default to 6 places, with 2, 4, 6, and 10 available. Positive durations below half a second have an explicit note so they are not mistaken for an exact zero. Actual transfer time can differ because bandwidth and other conditions vary.
Rate displays also round halfway up, rather than always upward. A rounded required rate may be slightly below the exact threshold, so the result includes the exact stated-rate fraction when rounding occurs. Positive rates or entered times that display as zero receive an explanatory note. Allow headroom for changing conditions; target planning is not a guarantee of connection performance.
Volumes use cubed length conversions
The Volume Calculator covers rectangular prisms, cylinders, cones, and spheres. Dimensions must be positive, with up to 15 integer digits and 10 decimal places, and use the same selected length unit: m, cm, mm, ft, or in. Only the selected shape’s dimensions are used. Circular shapes use the radius; the height of a cone is perpendicular to its base.
Length conversion factors are cubed to obtain volumes in m³, cm³, mm³, ft³, or in³. One liter is exactly 0.001 m³, and one milliliter is exactly 1 cm³. The international foot is exactly 0.3048 m and the inch exactly 0.0254 m. Dimensions and conversion factors remain exact integer fractions. Shapes involving π retain an exact coefficient of π and use a separate 120-significant-digit decimal configuration for the displayed approximation.
Results default to 6 decimal places, with 0, 2, 4, 6, and 10 available. Exact halfway values round up. Results involving π always show ≈; rectangular-prism results show it when display rounding changes the exact value. A positive volume that rounds to zero is explained. Changing the displayed unit or precision uses the original result.
Weighted averages divide by the total weight
The Weighted Average Calculator accepts 2 to 20 rows and calculates Σ(value × weight) ÷ Σweight. Values may be negative, zero, or positive. Weights must be nonnegative, with at least one positive weight. Every row needs a valid value and weight, including rows with zero weight. Each input accepts up to 15 integer digits and 10 decimal places.
Weights do not need to add up to 100. The calculator divides by their actual total, so weights of 1 and 3 give the same average as 25 and 75. Values must use the same unit and scale; different score scales or units are not converted automatically.
A separate 100-significant-digit decimal configuration preserves weighted products and sums within these limits. Displayed ratios are rounded directly from their numerator and denominator, with 2 decimal places by default and every whole-number choice from 0 through 10 available. Exact ties round away from zero, ≈ identifies a rounded value, and a rounded zero has no minus sign. Individually rounded weight shares may not total exactly 100%, and displayed contributions may not sum to the displayed average.
Number base conversions keep integers exact
The Number Base Converter supports bases 2, 8, 10, and 16. It accepts up to 256 digits, excluding an optional leading + or - and a prefix matching the selected base: 0b, 0o, or 0x. Hexadecimal letters are case-insensitive. Leading zeros count toward the input limit.
Fractions, digit separators, and spaces between digits are not accepted; surrounding whitespace is ignored. Digits are interpreted in the selected base. For example, hexadecimal 0B means decimal 11, and hexadecimal 1E3 means decimal 483.
BigInt preserves the integer throughout conversion, with no rounding or precision selector. Outputs omit prefixes and unnecessary leading zeros, use uppercase A–F for hexadecimal, and normalize negative zero to zero. Negative results have a leading minus sign; they are not fixed-width two’s-complement representations. The binary digit count describes the magnitude only and does not include a sign bit.
Loan payments use a stated cent-rounding schedule
The Loan Payment Calculator assumes a fixed nominal annual interest rate and monthly payments, with the first payment one month later. The loan amount must be positive, with up to 15 integer digits and 2 decimal places. The annual rate can be 0–100%, with up to 10 decimal places, and the term must be a whole number from 1 to 600 months.
The monthly rate is the entered annual percentage divided by 1,200. The regular payment uses the loan amortization formula, or principal divided by months at 0%. Exact integer fractions preserve the calculation until it is rounded to cents; exact half-cent values round up. Each month’s interest is also rounded to cents using the opening balance. The last payment clears the remaining balance and interest, and totals are the sums of the actual schedule.
Rounding can pay off a small loan early or leave a larger final payment. A regular payment that rounds to zero or covers only interest is explained. Schedule amounts use two decimal places without ≈ because they are the cent amounts determined by this model. They remain estimates of a real loan: fees, APR, variable rates, taxes, insurance, daily interest, and extra or late payments are not modeled.
Compound interest keeps fractional cents between periods
The Compound Interest Calculator accepts an initial deposit and a contribution per period, each from 0 to 1,000,000,000,000 with up to 2 decimal places. The initial deposit is required; a blank contribution means zero. The nominal annual rate can be 0–100%, with up to 10 decimal places, and the duration is a whole number from 1 to 50 years.
Compounding and contributions share the same schedule: annually, quarterly, or monthly. Contributions occur at the beginning or end of each period, with the same number of contributions in either case. Changing frequency keeps the entered contribution amount; adjust it to match your intended schedule. At 0%, the final value is the initial deposit plus all contributions.
A separate 100-significant-digit decimal configuration calculates the projection without rounding interest to cents between periods. The final value, total deposits including the initial amount, interest, and cumulative yearly breakdown display 2 decimal places, rounding exact ties up and showing ≈ when display rounding changes the value. This is a fixed-rate projection, not a bank posting schedule. Fees, taxes, inflation, changing returns, withdrawals, and daily calendar-based interest are excluded.
Date offsets combine years and months before adjusting the day
The Date Calculator adds or subtracts calendar units within Gregorian years 0001–9999. One direction applies to all units. Years, months, weeks, and days are required nonnegative whole numbers; enter 0 for an unused unit. Individual limits are 9,998 years, 119,987 months, 521,722 weeks, and 3,652,058 days. A combined offset must also stay within the supported date range.
First, years and months form one shift of 12 × years + months. If the original day does not exist in the destination month, it is adjusted once to that month’s last day. Then 7 × weeks + days calendar days are applied. Subtraction follows the same order in the opposite direction. For example, February 29, 2024 plus one year and one month is March 29, 2025.
Results show the date, weekday, exact calendar-day difference, and any month-end adjustment. The calculation does not preserve month-end status or guarantee that reversing an offset restores the original date. Gregorian leap-year rules apply throughout the range, including dates before the calendar’s historical adoption. There is no decimal rounding, time-zone or daylight-saving adjustment, and weekends and public holidays are included.
Standard deviation depends on the sample or population choice
The Standard Deviation Calculator accepts up to 200 values in 13,000 characters. Each value can have up to 15 integer digits and 10 decimal places. Negative numbers, zero, and repeated values are accepted. The default one-per-line format ignores blank lines and permits correctly grouped thousands separators. In comma-separated mode, commas only separate values and empty entries are rejected.
The default Sample mode requires at least 2 values and divides the sum of squared deviations from the mean by n − 1. Population mode requires at least 1 value and divides by n. Standard deviation is the square root of the resulting variance. A one-value population, or any valid list of identical values, has zero variance and standard deviation. Standard deviation uses the input unit; variance uses its square.
The calculation preserves the exact input values and variance until the final rounding, including when large values have very small differences. Results default to 4 decimal places, with 0, 2, 4, 6, and 10 available. Exact ties round away from zero, and ≈ appears when a displayed statistic differs from its exact value. A positive variance or standard deviation that rounds to zero has an explanatory note. Changing display precision uses the original statistics.
GCD and LCM use exact integers and stated zero conventions
The GCD and LCM Calculator accepts 2 to 20 integers, up to 100 digits each excluding an optional sign, in at most 4,096 characters. Leading zeros count toward the limit. Commas, spaces, and line breaks separate values; commas never group thousands. Enter 1000 for one thousand. Empty comma-separated entries, decimals, fractions, and scientific notation are not accepted.
Calculations use absolute values and return nonnegative results. If a list contains a nonzero value, its GCD is the greatest positive integer that divides every value. For nonzero values, its LCM is the smallest positive common multiple. This calculator defines the GCD of an all-zero list as 0 and the LCM of any list containing zero as 0. These zero cases are conventions, not claims about a greatest positive divisor or a smallest positive multiple.
Results are exact, with no rounding. The main GCD and LCM are shown in full even when long. Calculation steps explain the first pair and how further values are combined. Long step sequences and intermediate or recent-history previews may be shortened with an explanation; this does not shorten the numbers used in the calculation.
The Rounding Calculator applies the rule you choose
The Rounding Calculator accepts plain decimal input with up to 100 digits before and 100 after the decimal point, in at most 220 characters. Signs are allowed; commas, expressions, and exponent notation are not. Choose −20 to 20 decimal places, or 1 to 20 significant figures. Negative decimal places round to larger units: −1 means tens and −2 means hundreds.
The default rounds to the nearest value, with exact ties away from zero. Ties to even chooses an even final retained digit at a midpoint. Floor moves toward negative infinity, ceiling toward positive infinity, and truncation toward zero. The comparison uses the same original number and precision for all five methods, so their different effects on negative numbers are visible.
The input decimal and midpoint decisions are exact. The result is the output of the selected rule, and a note says whether its numeric value changed; this tool does not use ≈. Scientific notation makes the requested significant figures explicit, including after a carry: 9.99 to 2 figures becomes 1.0 × 10^1. A secondary decimal value shows the same number. Negative zero is normalized to zero. For zero at 3 figures, 0.00 × 10^0 is a display convention; adding zeros does not establish measurement accuracy.
Quadratic roots use the exact discriminant for classification
The Quadratic Equation Calculator solves ax² + bx + c = 0. All three coefficients are required and may be negative, zero, or positive, with up to 15 integer digits and 10 decimal places each. Correctly grouped thousands separators are accepted; fractions, expressions, and exponent notation are not.
For a nonzero a, the exact discriminant Δ = b² − 4ac determines the solution type: two distinct real roots when positive, one repeated real root when zero, and two complex-conjugate roots when negative. If a is zero, the calculator solves the linear equation when b is nonzero. If both a and b are zero, c = 0 gives infinitely many solutions; any nonzero c gives no solution.
Rational roots and components stay exact until display rounding. Irrational square roots use a separate 120-significant-digit calculation designed to preserve a small root even when the other root is much larger. Real roots are listed from smallest to largest; complex roots use opposite signs for the imaginary component.
Results default to 6 decimal places, with 0, 2, 4, 6, and 10 available. Exact ties round away from zero. Rational values show ≈ when display rounding changes them; irrational roots always show it. Notes identify distinct roots that look equal at the chosen precision and nonzero values that round to zero. The displayed rounding never changes the solution type. The coefficients are treated as mathematical values, without measurement uncertainty or automatic unit handling.
Triangle measurements and supported input methods
The Triangle Calculator defaults to three positive side lengths in the same unit (SSS), each with up to 15 integer digits and 10 decimal places. The longest side must be strictly shorter than the other two combined. Lengths such as 1, 2, and 3 do not form a nondegenerate triangle and are rejected. Units are not converted automatically.
Heron’s formula gives the area from the three sides. The perimeter is their sum, and the perpendicular height to each side is twice the area divided by that side. Angle A is opposite side a, B is opposite b, and C is opposite c. Angles are displayed in degrees. Side equality and exact comparisons of squared lengths determine the triangle’s classification before rounding.
In SSS, the area and heights are rounded directly from their exact squared values. General angles use a separate 120-significant-digit calculation; angles of 60°, 90°, or 120° established by exact side relationships are identified as exact. Results default to 6 decimal places, with 0, 2, 4, 6, and 10 available. Exact ties round up, and ≈ identifies rounded lengths or areas and approximate angles.
Optional ASA/AAS accepts angles A and B in degrees and one selected side a, b, or c. Both angles must be positive and their sum strictly below 180°. C is their exact complement to 180°, and the sine rule gives the missing lengths. Optional SAS accepts a, b, and their included angle C, strictly between 0° and 180°. It uses the cosine rule in a stable half-angle form and area K = ab sin C ÷ 2. The non-included-angle SSA case is not supported.
The optional methods keep the same input digit limits and use independent 120-significant-digit trigonometry. Entered values, exact angle sums, symmetry, and supported special-angle square relationships are retained. Known rational values and exact square-root ratios are rounded using integer midpoint comparisons. Other derived values carry ≈ as numerical approximations. No displayed value is reused to calculate a subsequent result. ASA/AAS classification uses the exact input angle relationships; SAS uses the included angle, side equality, and unrounded angle-sign relationships.
Independently rounded angles may not add up to exactly 180°. A note explains when a positive length or area displays as zero, or an angle displays as 0° or 180° at the selected precision. These displays do not make the original triangle degenerate. Length results use the input unit and area uses its square. This tool covers plane geometry, without survey corrections or measurement uncertainty.
Combinations and permutations count different selection rules
The Combinations and Permutations Calculator accepts n distinct available items or types and r selections or positions. Both must be whole numbers from 0 to 1,000, with at most 32 input characters per field. Surrounding whitespace and leading zeros are allowed; signs, commas, decimal points, and exponent notation are not.
Without repetition, ordered selections use n! ÷ (n − r)! and unordered selections use n! ÷ [r! × (n − r)!] when r ≤ n. With repetition, ordered selections use n^r, and unordered selections use C(n + r − 1, r) for n ≥ 1. Repetition means a type may be chosen again with unlimited supply; it does not mean arranging an existing collection that contains identical copies.
Every mode returns 1 when r = 0, including when n = 0: there is one empty selection. If n = 0 and r is positive, the result is 0. Without repetition, r greater than n also gives 0 because the selection is impossible. These cases are handled separately, without taking a factorial of a negative number.
Counts are exact integers with no rounding or precision selector. The selected result shows every digit; long comparison values and recent-history entries may use an explicitly shortened preview with the digit count. The calculator compares all four rules and explains the chosen formula. It does not generate a list of possibilities, calculate probabilities, or model limited supplies, forbidden positions, or circular arrangements.
Pace and split times use the original distance and time
The Pace Calculator requires a positive distance of no more than 1,000 km or its equivalent in miles, with up to 15 integer digits and 10 decimal places. One international mile is exactly 1.609344 km. Presets use 5 km, 10 km, 21.0975 km for a half marathon, and 42.195 km for a marathon. Selecting a preset fills the distance and kilometer unit while keeping your entered time.
Elapsed hours must be a whole number from 0 to 9,999; minutes and seconds must each be from 0 to 59. Blank time components mean zero, but the total must be at least one second. Pace is time divided by distance, while average speed is distance divided by time. Unit conversions and these ratios stay exact until display.
Pace displays total minutes:seconds per kilometer or mile, rounded to the nearest second. Speeds display 2 decimal places. Exact halfway values round up, and ≈ marks display rounding. A note identifies a positive pace or speed that rounds to zero. These display precisions are fixed.
The optional split table shows cumulative times every kilometer or mile, including a final partial interval when needed, with at most 1,000 rows. Every time is calculated from the original distance and elapsed time, so rounded pace values do not accumulate. The finish time equals the entered total. Changing the split unit or expanding the table does not add a history entry. Splits assume a constant pace; they do not account for terrain, changing effort, or stops beyond what is included in your entered time.
Recipe scaling keeps the same serving size and ingredient units
The Recipe Scaler multiplies each ingredient amount by target servings ÷ original servings. Both serving counts must be greater than zero and no more than 1,000. Decimal servings such as 0.5 are allowed, with up to 10 decimal places. The calculation assumes the same size for each serving.
Enter 1 to 20 ingredients. Names are optional, up to 60 characters, and units are optional, up to 24 characters. Every ingredient needs a nonnegative amount: enter 0 for none or remove the row. Amounts accept plain decimals, simple fractions, or mixed numbers such as 0.5, 1/2, or 1 1/2. A denominator must be positive, and the fraction within a mixed number must be less than one; improper fractions such as 3/2 are also accepted.
Decimal amounts accept up to 15 integer digits and 10 decimal places. Fraction and mixed-number parts each allow up to 15 digits, within 64 input characters. Do not put commas, negative signs, units, exponent notation, or characters such as ½ in an amount. The exact serving ratio and ingredient quantities are retained as fractions. Their decimal displays default to 4 places, with 0, 2, 4, 6, and 10 available. Exact ties round up, and ≈ marks a changed decimal value. Changing precision does not change the exact quantities.
Each ingredient keeps its entered unit. The calculator does not convert cups to grams, use ingredient densities, round to practical measuring sizes, or adjust cooking time and temperature. If a positive quantity displays as zero in the decimal column, a note points to its exact quantity or a higher display precision. Scaling the quantities is an arithmetic adjustment, not a guarantee of the cooking result.
Margin and markup use different bases
The Margin & Markup Calculator uses profit per unit = selling price − cost. Margin divides that profit by the selling price; markup divides it by the cost. Comparing a price with its cost allows a loss, zero cost, or zero price. A percentage with a zero denominator is shown as not defined.
Calculating a price from a target percentage requires a positive cost. Target margin ranges from 0% to below 100%, while markup ranges from 0% to 1,000,000%. Amounts accept up to 15 integer digits and 10 decimal places, with correctly grouped thousands commas. Exact fractions preserve intermediate prices and ratios; only the displayed values are rounded, with midpoint ties away from zero and ≈ when a value changes.
All amounts use the same currency. These are gross per-unit comparisons based on the cost entered. Taxes, fees, overhead, and other expenses are not automatically included, and rounding a proposed selling price can change its actual margin.
Break-even whole-unit thresholds use exact values
The Break-Even Calculator models one product at a fixed selling price and variable cost per unit. Fixed costs and any target profit must use the same period and currency. Inputs accept up to 15 integer digits and 10 decimal places. Fixed and variable costs are nonnegative; the selling price must be positive and exceed variable cost for this model.
Contribution per unit is price − variable cost. The theoretical break-even quantity is fixed costs ÷ contribution; the minimum whole-unit quantity is its exact ceiling. The target-profit quantity uses (fixed costs + target profit) ÷ contribution. Whole-unit thresholds are never calculated from a rounded decimal. Sales and profit at those quantities can differ from the theoretical equality, and the preceding whole-unit quantity provides a useful check.
With zero fixed costs and positive contribution, zero sales breaks even. Nonpositive contribution is outside this tool's model: even when zero sales gives zero profit, extra sales cannot build positive profit. Results do not forecast demand or account for changes in price, costs, taxes, or production capacity.
Ohm's law calculations use a resistive DC model
The Ohm's Law Calculator uses voltage V, current I, resistance R, and power P with V = I × R and P = V × I. Choose two known quantities from six pairs. Values must be positive magnitudes for this model; zero and negative values are outside this tool's input scope.
Input units convert to volts, amperes, ohms, and watts before calculation. Decimal values and unit factors are retained as exact fractions. Square-root results are rounded directly from the exact ratio at the selected display precision. ≈ marks a changed display value; a positive result that displays as zero is identified. Displayed decimals are not reused to calculate the other quantities.
This tool assumes an ideal ohmic load at steady DC conditions. It does not model reactive AC impedance, changing resistance with temperature, nonlinear devices, component tolerances, or equipment ratings. Use the separate Electricity Cost Calculator to estimate energy use over time.
Linear systems are classified with exact coefficients
The System of Equations Calculator solves a*x + b*y = c and d*x + e*y = f. Each coefficient is a signed decimal, including zero. Exact fraction arithmetic determines whether there is one solution, no solution, or infinitely many solutions; classification does not use a floating-point tolerance.
For a unique solution, the determinant is a*e − b*d, with x = (c*e − b*f) / determinant and y = (a*f − c*d) / determinant. Exact fractions and decimal displays are separate. If the determinant is zero, the tool also checks consistency, including rows such as 0*x + 0*y = 1. No solution and infinitely many solutions are mathematical results, not invalid input.
Two variables remains the default. The optional Three variables mode accepts three equations of the form a*x + b*y + c*z = d. Exact Gauss–Jordan row reduction finds x, y, and z, identifies contradictions, or describes the full family in terms of free variables. It shows coefficient and augmented ranks, exact row-operation steps, and three substitution residuals for a unique solution.
Coefficients accept up to 15 integer digits and 10 decimal places with correctly grouped thousands commas. Display rounding uses the selected decimal places with exact halfway values away from zero. A small nonzero determinant is never changed to zero for classification. This tool covers two or three linear equations in the matching number of variables, without parsing full equation strings or solving nonlinear systems. Switching modes clears the old result but preserves inputs; Reset returns to the empty two-variable form with six decimal places.
Aspect ratio and pixel dimensions are different results
The Aspect Ratio Calculator divides positive width by height and simplifies their exact ratio. Inputs can be dimensions in the same unit or ratio terms such as 16 and 9. Decimal values accept up to 15 integer digits and 10 decimal places. A ratio describes shape; it does not determine an image's resolution.
An optional target width or height must be a whole number of pixels from 1 through 1,000,000,000. The other dimension is derived from the original exact ratio. The tool distinguishes the ideal dimension from the nearest whole-pixel frame, with halfway pixels rounded upward. Whole-pixel rounding can change the aspect ratio. If the derived dimension rounds to zero pixels, no valid whole-pixel frame is presented; choose a larger target.
An optional positive screen diagonal in inches or centimeters gives physical width and height using D × W ÷ √(W² + H²) and D × H ÷ √(W² + H²). The international inch is exactly 2.54 cm. This calculation uses a separate 100-significant-digit decimal context for the square root and unit conversions, then rounds the displayed values. Very small positive dimensions show a less-than threshold instead of a zero-sized screen. It models the active area of a flat rectangular display; bezels, casing, stands, and curved panels are excluded.
Changing decimal display precision does not change the exact ratio or the whole-pixel result. Presets change the source ratio, while entered target dimensions remain available for recalculation. No image file is uploaded, cropped, padded, or resized by this tool.
Final grades use a two-part weighted model
The Final Grade Calculator treats the current grade as the normalized grade for all work other than the final exam. With final weight w expressed as a fraction, the course grade is current × (1 − w) + exam × w. Entered grades and the final weight must be between 0 and 100 percent. Letter-grade cutoffs, curves, extra credit, dropped scores, and separate exam pass requirements are not included.
For a positive final weight, the exact exam threshold is (target − current × (1 − w)) / w. Exact fractions determine whether the target is already secured, achievable, or above the 100% exam limit. A displayed rounded threshold does not change that classification. A separate minimum for scores in increments of 0.01 percentage points uses upward rounding; this is a planning increment, not a claim about your school's grading rules.
At 0% final weight, the final cannot change the course grade and no unique exam threshold is calculated. At 100% weight, only the final score contributes. Input values remain exact, and ordinary decimal displays round halfway away from zero. Check that your gradebook's current grade excludes the final and covers all other work before using this model.
Density is mass divided by volume
The Density Calculator solves density = mass / volume, mass = density × volume, or volume = mass / density using two positive quantities. It models mass density, not weight as a force, relative density, or a material lookup. Use measurements that describe the same sample and conditions.
Metric and customary values convert through exact fractions in kilograms and cubic meters. The international foot is exactly 0.3048 meters, the inch is 0.0254 meters, the avoirdupois pound is 0.45359237 kilograms, and the ounce is 1/16 of that pound. Cubic units use cubed length factors; density units divide their mass factor by their volume factor.
Numeric inputs accept up to 15 integer digits and 10 decimal places with correctly grouped thousands commas. Results round only for display, halfway away from zero, with ≈ for changed values and an explanation when a positive value displays as zero. Changing the output unit or decimal places reformats the original exact result and does not record a new calculation. Temperature, pressure, composition, and measurement uncertainty are not estimated.
Slopes and lines use exact coordinate differences
The Slope Calculator uses two signed coordinate pairs. Rise is y₂ − y₁, run is x₂ − x₁, and slope is rise divided by run. Exact fractions determine slope, intercept, midpoint, and the line equation without treating small nonzero differences as zero.
Distinct points with equal x coordinates define a vertical line with undefined slope. Equal y coordinates define a horizontal line with slope zero. Coincident points do not determine a unique line, but their midpoint and zero distance remain valid. These cases are mathematical results, not malformed input.
Midpoint averages each coordinate pair. Euclidean distance is the square root of the sum of squared coordinate differences; both axes must use the same unit for that distance to have a physical meaning. Exact fractions or radicals are retained before display rounding. Decimal displays use the selected precision, round halfway away from zero, and show ≈ when rounded. This is a Cartesian calculation, not a geographic distance calculation.
Scientific expressions use explicit functions and angle units
For an arithmetic or geometric progression, use the dedicated Sequence Calculator. Its inputs specify the progression directly instead of parsing a general expression.
The Scientific Calculator evaluates real-valued expressions with trigonometric and inverse trigonometric functions, logarithms, roots, powers, factorials, and constants. DEG interprets angles in degrees; RAD uses radians. Inverse trigonometric functions return their principal angle in the selected unit. log means base 10, ln means base e, and exp(x) means e raised to x.
Use explicit multiplication, as in 2*pi and 2*(3+4). Postfix factorial and percent come before powers; powers associate to the right and precede unary minus: 2^3^2 = 512, -2^2 = -4, and 2^-3 = 0.125. The percent sign still divides its operand by 100, so 200 + 10% = 200.1. Double factorial (!!) is not supported; applying factorial twice requires parentheses, as in (3!)!.
Calculations use an independent 80-significant-digit decimal context. Constants and numerical functions, intermediate rounding, or final display rounding can mark a result with ≈. An approximation marker can remain even when an expression simplifies to an exact value mathematically. Finite precision and cancellation can reduce accuracy; this is numerical evaluation, not symbolic algebra. Display precision changes reformat the saved result without adding history. Very large and small results use e notation.
Expressions allow 512 characters, 256 tokens, and 32 nesting levels. Number literals allow 30 mantissa digits and an entered e exponent from −1000 to 1000. Nonzero inputs, intermediate values, and results must have magnitude from 10−1000 through 101000. Power exponents are limited to ±1000, factorials to integers 0–170, and trigonometric input angles to magnitude 1,000,000 in the selected unit.
Division by zero, 0^0, nonpositive logarithm arguments, negative square-root arguments, and fractional powers of negative bases show an error. Use cbrt for negative cube roots. Tangent is rejected at undefined angles and when the computed absolute cosine is below 10−60, where evaluation is too close to a pole for this tool's precision. Complex arithmetic and equation solving are outside this calculator's scope.
Scientific notation arithmetic preserves the input values
The Scientific Notation Calculator accepts decimal and e-notation inputs such as 6.02e23. Each number allows up to 100 mantissa digits and 128 characters, with an entered exponent from −100 to 100. Commas, fractions, and expression strings are not accepted. Convert one number or add, subtract, multiply, or divide two numbers; division by zero shows an error.
Exact integer fractions preserve intermediate results, including cancellation between large values. Scientific notation, e notation, and the full decimal form show the same value rounded to the selected 1–20 significant figures. Exact midpoint ties round away from zero; ≈ marks a changed value. Carrying a rounded coefficient to 10 adjusts the exponent to keep nonzero coefficients between 1 and 10 in magnitude.
Trailing zeros reflect your selected display precision rather than inferred measurement accuracy. Zero uses an exponent of zero by convention. Selecting a different precision reformats the original result without adding a history entry.
Time addition and subtraction keep whole seconds exact
The Time Calculator adds or subtracts 1 to 20 duration rows. Each row accepts hours from 0 to 999,999,999, and minutes and seconds from 0 to 59. Hours allow at most 9 digits, and minutes and seconds at most 2 each, including leading zeros. Each component has a 32-character limit including surrounding whitespace. Use the row’s Add/Subtract selector instead of typing a sign; decimals, commas, and exponent notation are not accepted.
A blank component means zero, but a completely blank row is an error. Enter at least one explicit zero for a zero-duration row. Each row becomes 3,600 × hours + 60 × minutes + seconds, then its selected sign is applied. Totals and running totals preserve every whole second.
The main hours:minutes:seconds result does not wrap at 24 hours. A negative total has one sign applying to the entire duration: −0:00:01 means negative one second. Total seconds, added durations, and subtracted durations are also exact. This tool combines elapsed durations; it does not calculate clock times, dates, time-zone changes, daylight-saving changes, or overlaps between scheduled events.
Decimal hours divide total seconds by 3,600, and decimal minutes divide by 60. These displays default to 4 places, with 0, 2, 4, 6, and 10 available. They are rounded directly from the exact ratio, with midpoint ties away from zero and ≈ when the displayed value changes. Negative zero is removed from decimal displays, and a note identifies a nonzero duration that rounds to zero. Changing decimal places keeps the same duration and adds no history entry.
Sequences start at the first term
The Sequence Calculator uses a first term, a common difference or ratio, and a whole-number term count from 1 to 1,000. Arithmetic sequences add the difference at each step; geometric sequences multiply by the ratio. The nth term and the sum of the first n terms are distinct results.
Finite decimal inputs become exact fractions. Reduced numerators and denominators of calculated values are limited to 200 digits; an answer beyond the supported size shows a limit message instead of a shortened answer. Decimal display rounding uses the selected precision, with halfway values rounded away from zero and ≈ for changed values. The preview lists only the first terms, not the entire requested sequence.
A geometric infinite sum is distinct from the finite sum. For a nonzero first term, it exists only when the absolute ratio is less than 1. A zero first term generates an all-zero sequence with sum zero for any finite entered ratio. The first term remains the entered value when the ratio is zero. This tool does not infer a pattern from a list of numbers.
Binomial probabilities assume independent trials
The Binomial Probability Calculator models a fixed number of independent trials, each with two outcomes and the same success probability. Success probability is entered as a percentage from 0 through 100. Trial counts range from 0 through 1,000, and success counts are whole numbers from 0 through the trial count.
Exactly, at most, at least, and inclusive range events are calculated from exact integer probability weights. Complements use the exact result before rounding, so very small probabilities are not lost through subtraction of rounded values. Expected successes are n times the success probability, and are an average over repeated experiments, not a prediction of a single outcome.
Zero trials produce zero successes with certainty. A 0% or 100% success probability is deterministic. Decimal and percentage displays are rounded independently, halfway away from zero; ≈ identifies display rounding, including a positive chance that rounds to zero or a chance below certainty that rounds to 100%. Changing displayed precision does not record a new calculation. Sampling without replacement from a finite population generally does not meet the independence assumption.
Equivalent resistance depends on the connection
The Resistor Calculator combines 2 to 10 ideal, nonnegative resistances in one series connection or one parallel connection. Each row has its own Ω, kΩ, or MΩ unit. Exact fractions preserve conversion factors and arithmetic before final display rounding.
Series resistance is the sum of the resistances. For positive parallel resistances, the reciprocal of the equivalent resistance is the sum of their reciprocals. A zero-ohm parallel branch is an ideal short circuit and gives zero equivalent resistance; zero in series adds no resistance. All active rows are validated even when a short circuit determines the result.
Negative resistance, open circuits represented by infinity, and mixed network topologies are outside this tool's scope. Nominal resistance calculations do not include component tolerances, temperature effects, power ratings, or AC impedance. Output units and decimal places reformat the original result without adding history. Display ties round away from zero, and ≈ marks rounding.
Age is calculated with calendar dates
The Age Calculator uses a birth date and a reference date in the Gregorian calendar, from year 0001 through 9999. It finds the largest completed month offset from the original birth date, clamps a day missing from the target month to that month's last day, then divides the completed months into years and remaining months. Remaining days are counted from that month anniversary. Each month offset starts from the original birth date, avoiding repeated end-of-month adjustments.
A February 29 birthday uses February 28 in a nonleap year under this tool's convention. The next birthday includes the reference date itself; a birthday today is zero days away. A birthday beyond year 9999 is unavailable without invalidating the age result. These are calendar conventions, not a determination of legal eligibility or a jurisdiction's age rules.
Total elapsed days use calendar-day differences, with the birth date as day zero. The default reference date and Use today action use your device's local date. The calculation does not use time of birth, time zones, daylight-saving adjustments, or fractions of a day. Editing dates hides the previous result and does not add history.
Paint quantities depend on the coverage you enter
The Paint Calculator estimates paint from a known area or the four walls of a rectangular room, optionally including its ceiling. Excluded area is subtracted before multiplying by the number of coats. The result is divided by the product's one-coat coverage and multiplied by one plus your allowance percentage. Net area, coverage, and container size must be positive; coats range from 1 to 10 and allowance from 0% to 100%.
Metric inputs use meters, square meters, and liters. US inputs use feet, square feet, and US liquid gallons. Changing the unit system relabels the entered numbers; it does not convert them. Check every measurement and the coverage rate after changing units. A room with several paint products or coverage rates should be calculated in separate groups.
Exact fractions determine paint volume and the minimum whole number of equal-size containers, using an upward whole-container rounding before any display rounding. Purchase quantity and surplus use that container count. Decimal display ties round away from zero, and ≈ marks display rounding. This is an estimate based on your inputs; actual coverage depends on the product, surface, film thickness, and application. No universal coverage or coat count is assumed.
Pressure uses normal force over area
The Pressure Calculator solves P = F / A, F = P × A, or A = F / P for positive magnitudes. Force is perpendicular to the area. For a nonuniform load, total normal force divided by area gives average pressure. The tool does not add atmospheric pressure or infer whether your pressure is absolute, gauge, or a pressure difference.
Pa, kPa, MPa, bar, atm, and psi convert through exact factors. One standard atmosphere is 101,325 Pa, one bar is 100,000 Pa, and one pound-force is 4.4482216152605 N. The international inch is 0.0254 m and foot is 0.3048 m. Area conversions square those length factors; psi is derived from pound-force per square inch without a shortened conversion factor.
Known quantities are positive, with up to 15 integer digits and 10 decimal places. Exact fractions are retained until the final decimal display, with halfway values rounded away from zero. ≈ identifies rounding, including a positive value displayed as zero. Output-unit and precision changes reformat the original answer without adding a recent calculation. Fluid depth, material behavior, atmospheric conditions, and equipment ratings are outside this model.
Salary compares gross pay on a 52-week basis
The Salary Calculator converts gross pay using 52 weeks, 26 biweekly periods, 24 semimonthly periods, 12 months, or 4 quarters per comparison year. Hourly and daily amounts use your scheduled hours and workdays per week. Biweekly means every two weeks; semimonthly means twice per month. These are comparison assumptions, not a prediction of actual payroll dates or paid days in a calendar year.
Pay must be nonnegative. Scheduled hours must be positive and no greater than 24 times the number of workdays; workdays must be a whole number from 1 to 7. All amounts use the same currency. Taxes, benefits, overtime, unpaid leave, and exchange rates are excluded. Exact fractions are preserved through conversion; displayed amounts round halfway away from zero with ≈ when rounded and two decimal places by default.
Fuel economy distinguishes consumption from distance per fuel
The Fuel Economy Calculator divides a positive distance by the positive fuel used over that same distance, or converts a known positive economy rate. It supports L/100 km, km/L, US miles per gallon, and Imperial miles per gallon. Lower L/100 km means less fuel consumed per distance; higher km/L or MPG means more distance traveled per unit of fuel.
One mile is exactly 1.609344 kilometers, one US gallon is exactly 3.785411784 liters, and one Imperial gallon is exactly 4.54609 liters. These definitions and reciprocal conversions use exact fractions before display rounding. Results show up to six decimal places by default and ≈ when rounded. The tool does not calculate MPGe, official vehicle ratings, or trip cost; Fuel Cost handles cost estimates separately.
Percent error uses the magnitude of the reference
The Percent Error Calculator uses |measured − reference| / |reference| × 100. It also reports the signed difference, absolute error, and relative absolute error. Values must use the same unit and scale. Negative reference values are accepted, and percent error can exceed 100%. A zero reference leaves percentage and relative error undefined, even if the measured value is also zero; the signed and absolute differences remain available.
An optional nonnegative tolerance checks whether the exact, unrounded percent error is at most the entered percentage. Its allowed interval is the reference plus or minus the reference magnitude times the tolerance divided by 100. This is a user-defined comparison, not a confidence interval or an estimate of measurement uncertainty. Results round halfway away from zero for display only, with ≈ for changed values and a notice if a nonzero result rounds to zero.
Prime factorization uses exact positive integers
The Prime Factorization Calculator accepts whole numbers from 1 to 999,999,999,999. It divides out prime factors and reports their powers, the expanded product, and the count and sum of positive divisors. The number 1 is neither prime nor composite and has one positive divisor: 1. Negative numbers, decimals, expressions, and scientific notation are not supported.
All results use exact integer arithmetic without rounding. The input limit keeps the calculation bounded in a browser. The divisor preview shows up to the first 100 positive divisors in ascending order; the total count and sum include every positive divisor.
Concrete quantities use geometric volume and product yield
The Concrete Calculator multiplies the length, width, and depth of a rectangular slab or footing by a whole-number quantity from 1 to 1,000, then applies your chosen allowance from 0% to 100%. Dimensions must be positive. Each dimension has its own unit, and international foot, inch, and yard definitions are used for exact volume conversion.
Optional bag quantities divide the required volume by the positive mixed-concrete yield per bag and round up to whole bags. Use the yield stated for your product; dry bag weight alone does not determine mixed volume. The whole-bag decision uses exact values before display rounding. Displayed volumes round halfway away from zero, with ≈ when changed. Allowance and product yield are your assumptions, and calculated surplus does not guarantee material left over at the job site. The calculator does not determine structural dimensions, reinforcement, or a mix recipe.
Acceleration uses signed velocity along one axis
The Acceleration Calculator finds average acceleration with a = (v − u) / t. Solving final velocity with v = u + at or initial velocity with u = v − at assumes constant acceleration over the entered positive elapsed time. Signed values describe one common axis; negative acceleration does not always mean slowing down.
Conversions use exact metric and international mile/foot definitions. The standard-gravity unit g₀ is exactly 9.80665 m/s², a conventional reference rather than a measurement of local gravity. Intermediate arithmetic uses exact fractions; final displays round halfway away from zero with ≈ for rounded values and a notice if a nonzero value displays as zero. Changing the display unit or precision does not add a new history entry. Displacement and changes in direction across multiple axes are outside this model.
CAGR is an equivalent annual compound rate
The CAGR Calculator uses (ending value / starting value)^(1 / years) − 1, expressed as a percentage. The starting value must be positive and the ending value nonnegative. Duration may be entered in years or months, with 12 months per year, and must be between one month and 1,000 years. Use the same unit or currency for both values.
The growth multiple and total change use exact fractions. The annual root is a numerical approximation calculated with 80 significant digits before display rounding, and its result is marked ≈. Unchanged values give exactly 0%; a zero ending value gives −100% under this endpoint formula. The rate is an equivalent constant rate, not the actual change in each year. It does not account for deposits, withdrawals, fees, taxes, or changes in purchasing power, and does not predict future performance.
Frequency and wavelength use the entered wave speed
The Frequency & Wavelength Calculator solves v = fλ for one missing positive quantity and finds the period with T = 1 / f. The speed must describe the wave and medium being considered. The light-speed preset supplies exactly 299,792,458 m/s for light in a vacuum; it does not determine light speed in another medium or estimate sound speed.
Inputs and unit conversions use exact fractions. Final display rounding is halfway away from zero, with ≈ when a value changes. The period automatically uses seconds, milliseconds, microseconds, nanoseconds, or picoseconds for readability. A positive value too small for the selected display precision is identified rather than treated as an exact zero. Changing the output unit or precision reformats the stored result without adding a history entry.
Roman numerals follow a stated modern convention
The Roman Numeral Converter supports integers from 1 to 3,999 and the letters I, V, X, L, C, D, and M. The supported subtractive pairs are IV, IX, XL, XC, CD, and CM. Roman input is case-insensitive, but must match the modern numeral produced when its value is converted back. Internal spaces, overlines, zero, negative numbers, and fractions are not supported.
Historical and clock-face conventions vary; forms such as IIII are outside this tool's chosen convention. Decimal input accepts at most four digits, including leading zeros, and properly grouped thousands commas. Both modes have a 64-character raw input limit. Conversions and the symbol breakdown are exact and do not use rounding.
Simple interest does not compound
The Simple Interest Calculator uses I = P × (annual rate / 100) × years to solve interest, principal, annual percentage rate, or duration. The total is principal plus interest. Known durations must be positive and no greater than 1,000 years; a solved duration may be zero. Months convert at exactly 12 per year. A zero denominator that prevents a unique solution produces an explanation rather than an invented result.
Amounts and rates are nonnegative, and amounts must use the same currency or unit. Inputs and intermediate results use exact fractions; only displays are rounded halfway away from zero, with ≈ and a notice for nonzero values rounded to zero. This model does not include compounding, fees, repayments, taxes, or calendar day-count rules, and does not determine a regulated APR or a product's contractual charge.
Kinetic energy uses a classical translational model
The Kinetic Energy Calculator uses E = ½mv² to find energy, mass, or speed. Speed is a nonnegative magnitude, and mass must be positive. Solving mass requires positive energy and speed. It does not include rotational energy, potential energy, or relativistic corrections.
Unit factors and rational quantities are exact. A speed found through a square root retains its exact squared value until final display rounding; perfect roots can be exact, while rounded roots receive ≈. Final rounding uses halfway away from zero. The classical model is suitable when speeds are much smaller than the speed of light; a mathematical output does not establish that a high-speed physical calculation is valid.
Scale ratios compare drawing length with actual length
The Scale Converter treats A:B as drawing or model length to actual length after converting both to the same unit. Both sides and all lengths must be positive. It supports reductions and enlargements, solves either length, and finds a scale from two known lengths.
Exact unit definitions and fractions preserve the simplified integer ratio. Decimal lengths and the normalized ratio use final display rounding with ≈ when changed. Scale describes linear lengths; areas and volumes change by the square and cube of the length factor. A printed ratio assumes the drawing has not been resized, and this tool does not measure screen distances or correct map projection distortions.
Savings goals use a fixed monthly deposit model
The Savings Goal Calculator solves the monthly deposit needed for a positive target over 1 to 1,200 whole months. Current savings are nonnegative. The entered nominal annual rate is between 0% and 100% and is divided by 12 for monthly compounding. Deposits occur either at the end or beginning of each month; beginning deposits earn one extra month of interest.
Exact fractions preserve growth factors and the required deposit. The payment is rounded upward to the next 0.01 currency unit so that the modeled final balance meets the target. A target already covered by the growth of current savings needs zero additional deposit. Projected balances use that rounded-up payment, while auxiliary displays round halfway away from zero and use ≈ when changed. This model assumes an unchanged rate and does not include monthly bank rounding, taxes, fees, withdrawals, inflation, or an interest-rate forecast.
Integer division uses a nonnegative remainder
The Remainder Calculator accepts a signed integer dividend and a positive integer divisor. Its main answer satisfies dividend = divisor × quotient + remainder with the remainder at least zero and less than the divisor. The quotient is rounded down toward negative infinity. All values are exact integers; decimal rounding is not used.
For negative dividends, the page also shows truncation toward zero, whose remainder can be negative. These conventions give different valid decompositions. Inputs allow up to 128 digits, including leading zeros, and 256 raw characters per field, with optional signs and correctly grouped commas. Divisors of zero or less, decimals, and expressions are not accepted. The Standard Calculator's percent key continues to mean division by 100.
Flooring boxes are rounded up from unrounded coverage
The Flooring Calculator starts with a positive area or rectangular room dimensions, adds a user-selected allowance from 0% to 100%, and divides by the product's positive coverage per box. The whole-box count is rounded upward using exact fractions. International feet and inches are converted before the area calculation, and one square foot is exactly 0.09290304 square meters.
The page distinguishes net area, required coverage, purchased coverage, and surplus beyond the allowance. An optional price per box gives a material-only total. Display rounding does not affect the box count. This is an area estimate, not a board or tile cutting layout; patterns, offcuts, installation conditions, and manufacturer instructions may change what must be purchased.
ROI includes entered costs and income over one holding period
The ROI Calculator divides net profit by total cost and multiplies by 100. Total cost is initial investment plus additional costs; total proceeds are ending value plus separately received income. Initial investment must be positive. Other amounts must be nonnegative, with blank optional costs and income treated as zero. Enter all amounts in the same currency and do not count fees or income twice.
Exact integer fractions preserve the calculation until display. Results default to at most 2 decimal places, with 4, 6, and 10 available; exact ties round away from zero. Rounded results use ≈, with an explanation for a nonzero value displayed as zero. This is a simple holding-period return, not an annualized return or a cash-flow-timing model. Borrowing, automatic taxes, inflation, and future performance are not modeled.
Net force uses a positive mass and a consistent direction
The Force Calculator solves F = ma for net force, mass, or acceleration in a one-dimensional, constant-mass classical model. Force and acceleration may be signed; mass must be positive. An inverse mass calculation requires nonzero force and acceleration with matching signs. Zero or inconsistent inputs that cannot determine a positive mass are explained.
Exact integer fractions preserve unit conversions and arithmetic. Pound mass is exactly 0.45359237 kg, standard gravity is exactly 9.80665 m/s², and pound-force is their product in newtons. This standard gravity is a conversion definition, not a measurement of local gravity. Final results use at most 6 decimal places by default, with 2, 4, 6, and 10 available. Output-unit and precision changes reformat the original answer without adding history.
Circle sectors distinguish an arc from a complete circle
The Circle Sector Calculator uses a positive radius and an angle greater than zero and no greater than one full turn. It calculates arc length, sector area, chord length, and boundary perimeter. With the angle in radians, arc length is rθ and area is r²θ ÷ 2. A full circle has a zero-length chord and a perimeter equal to its circumference; the radius is not added to that boundary.
Degree and radian inputs are supported, including explicit π and 2π radian constants. Numeric radians are checked against 2π without snapping nearby decimal inputs to a full circle. Results use the radius unit, with its square for area. Results involving π or general trigonometric functions are approximations; exact special-angle chords are identified separately. Display rounding is applied only after calculation. Changing display precision does not add a new history entry; changing an input unit keeps the typed number and clears the old result.
Sales tax uses your rate and rounds the tax once
The Sales Tax Calculator adds tax to a pre-tax amount or extracts included tax from a total. Enter a nonnegative amount with up to two decimal places and a rate from 0% to 1,000%. It does not look up rates, exemptions, or which items are taxable.
Tax is calculated as an exact fraction and rounded once to hundredths of a currency unit, with halfway values rounded up. In add mode, total = entered net amount + rounded tax. In remove mode, net amount = entered total − rounded tax. These displayed amounts always reconcile. This single-total estimate may differ from per-item rounding or the rules for an actual invoice.
Surface area includes the faces of a closed solid
The Surface Area Calculator measures a rectangular prism, sphere, right circular cylinder, or right circular cone. All dimensions must be positive. Total cylinder area includes both circular bases; total cone area includes one base. The cone's slant height is calculated from its radius and perpendicular height.
Length units use exact conversion factors and area units use their squares. Rational areas retain exact fractions; results involving π or an irrational square root use high-precision decimal arithmetic and carry an approximation mark. Rounding happens at display. Open faces, wall thickness, holes, seams, and material waste are outside this model.
Power is energy transferred per unit of time
The Power Calculator uses P = E ÷ t to solve average power, energy, or duration. Known time must be positive, and power and energy must be nonnegative. For duration, positive energy at zero power has no finite answer; zero energy and zero power do not determine a unique answer. Zero energy at positive power gives a target duration of zero, not a definition of average power over a zero-length interval.
Conversions are exact: 1 W = 1 J/s, 1 Wh = 3,600 J, and 1 kWh = 3,600,000 J. Fractions are preserved until final display rounding. Estimating a duration assumes a constant transfer rate. The calculator does not infer instantaneous power, efficiency, power factor, or electricity cost.
Business days use the calendar you specify
The Business Days Calculator counts working dates or moves a date by a signed number of business days. Choose a weekend pattern and supply any excluded holidays. Duplicate holidays count once, and a holiday on a weekend is not subtracted twice. Country-specific or observed holidays are not added automatically.
For a date range, the default excludes the start date and includes the end date; both choices are explicit. Date offsets exclude the starting day, count only working days in the chosen direction, and leave the start unchanged for an offset of zero. Gregorian dates from 0001 through 9999 are handled without time zones or daylight-saving adjustments. A business-day count does not determine contractual, legal, or delivery deadlines.
Z-scores measure distance from a mean
The Z-Score Calculator uses z = (x − mean) ÷ standard deviation or x = mean + z × standard deviation. The supplied standard deviation must be positive and must describe the same scale as the value and mean. Signed values are supported.
Exact fractions are retained until display rounding. Whether a value is above or below the mean is determined before rounding, even if a tiny difference displays as zero. Standardization does not require a normal distribution, but a z-score alone does not give a percentile or probability. This tool does not calculate a standard error or perform a statistical test.
Torque uses distance and the force angle
The Torque Calculator uses the magnitude τ = rF sinθ for one force. The distance r runs from the pivot to the point of application; the perpendicular moment arm is r sinθ. Angles range from 0° to 180°. Known distances must be positive, and forces and torques must be nonnegative. Inverse cases with a zero denominator distinguish an impossible condition from one with no unique answer.
Unit conversions and supported exact sine values retain exact fractions. Other angles use high-precision decimal trigonometry. Only the displayed answer is rounded, with approximation and rounded-zero notices. A calculated zero distance or force is allowed when uniquely determined. The result does not specify rotation direction, a fastener setting, or structural suitability; torque in N·m is distinct from energy in joules.
GPA uses the grade points and credits you enter
The GPA Calculator divides the sum of course credits × grade points by the total included credits. Grade points range from 0 to 4, and each included course needs positive credits. This is a credit-weighted average, not an automatic honors or AP weighting system.
Exact fractions preserve course quality points and totals until display rounding. A school's official GPA can differ because of its grade-point mapping, truncation, repeated-course rules, or exclusions. Enter only the courses and credits that belong in your calculation; the tool does not decide which courses count toward an official transcript.
APY reflects a stated compounding model
The APY Calculator converts between a nominal annual interest rate and an effective annual yield using APY = (1 + r/n)n − 1, where n is the chosen number of equal compounding periods. The inverse uses r = n × [(1 + APY)1/n − 1]. Both r and APY are decimal rates in these formulas; the calculator accepts and displays percentages.
The model assumes a fixed nonnegative rate with interest reinvested and no fees, taxes, deposits, or withdrawals. Daily means 365 equal periods; actual calendar and bank posting rules are not inferred. Nominal interest rate is not a loan's fee-inclusive APR. Exact arithmetic is preserved where possible, roots are evaluated numerically when needed, and only final displays are rounded. The result is a mathematical comparison, not a regulatory disclosure or a promised return.
Momentum retains the sign of velocity
The Momentum Calculator uses the classical one-dimensional relation p = mv to solve momentum, mass, or velocity. Mass must be positive. Momentum and velocity may be negative to represent motion opposite your chosen positive direction. A rounded display of zero does not erase the underlying sign.
Unit conversions and divisions keep exact fractions until display rounding. Mass cannot be inferred uniquely from zero momentum and zero velocity; other inconsistent zero or sign conditions are explained. This tool does not model collisions, vector addition, or relativistic momentum. High-speed notices identify limits of the classical formula rather than changing its result into a relativistic calculation.
Percentage difference uses a symmetric reference
The Percentage Difference Calculator uses 100 × |a − b| ÷ [(a + b)/2] for two nonnegative values in matching units. Swapping the values leaves the answer unchanged. One zero and one positive value give 200%; two zeros have an undefined relative difference because the denominator is zero.
This is the arithmetic-mean convention for percentage difference. It is distinct from percentage change, which uses an original value, and percentage error, which uses an accepted reference. Negative inputs are outside this tool's stated scope. Exact fractions retain the mean and difference until final display rounding.
Correlation describes paired observations
The Correlation Calculator computes Pearson’s r for 2–100 matched observations of two variables. Each line in X is paired with the same line in Y; missing interior lines are errors rather than silently shifting the pairs. Either variable being constant makes r undefined.
Exact integer sums preserve small differences even when the original values are large. Squared correlation is calculated before r is rounded. The sign and whether correlation is exactly perfect are determined from the unrounded quantities. A rounded value of ±1 is not necessarily an exact perfect correlation. Pearson’s r measures linear association, not causation, and this calculator does not provide significance tests or confidence intervals.
Capacitors use ideal series or parallel connections
The Capacitor Calculator combines 2–20 positive capacitances. Parallel capacitances add directly; a series connection uses 1/C = 1/C₁ + 1/C₂ + …. Each component may use its own pF, nF, µF, mF, or F unit.
Exact unit ratios and fractions are preserved until display rounding. The model is for one series chain or one parallel group of ideal capacitors. It does not infer a mixed circuit, voltage rating, polarity, leakage, resistance, tolerance, or safe operating conditions. Changing the output unit or precision redisplays the original result without adding a recent calculation.
Depreciation uses a straight-line estimate
The Depreciation Calculator spreads cost minus residual value over 1–50 full years. All amounts use the same currency and two decimal places. Annual and monthly estimates are calculated from the exact depreciable amount.
The annual schedule rounds accumulated depreciation to the nearest cent, then takes differences between consecutive totals. This keeps expenses, accumulated depreciation, and closing book values consistent, ending at the entered residual value. Annual rows may differ by one cent. Monthly figures are estimates rather than a monthly posting schedule. Tax allowances, partial years, impairment, and changing asset values are not inferred.
Linear regression fits a line with an intercept
The Linear Regression Calculator fits an unweighted least-squares line to 2–100 paired observations. Exact integer sums and fractions preserve the slope, intercept, and predictions before display rounding. The model includes an intercept and minimizes squared vertical residuals.
X must vary. If Y is constant, the fitted line is horizontal and R² is undefined because total Y variation is zero. Optional predictions use the unrounded line, with an extrapolation notice outside the observed X range. A fitted line or high R² does not establish causation, statistical significance, or reliable future predictions.
Mechanical work depends on direction
The Work Calculator uses W = Fd cos θ for a constant force and a straight displacement. Force and displacement are nonnegative magnitudes; the angle is 0–180 degrees. Work can be positive, zero, or negative.
Unit conversions are exact. Standard angles with exact supported cosine values retain exact fractions; other angles use high-precision numerical evaluation. Zero factors and inconsistent inverse inputs receive distinct explanations. The model does not integrate a changing force along a path. Energy is expressed in joules and related units, and is distinct from torque.
Energy conversion retains exact unit factors
The Energy Converter converts eight units through joules, retaining exact integer fractions. Calories and kilocalories use the thermochemical definition (4.184 J per cal); BTU uses the International Table definition (1,055.05585262 J per BTU). Zero and signed energy changes are accepted.
Only displayed values are rounded, halfway away from zero, with ≈ for rounding and a notice when a nonzero selected result displays as zero. Target-unit and precision changes reuse the unrounded quantity and do not add history. Energy units are distinct from power units such as kW or BTU/h, which require a duration to determine energy.
Each calculator explains its formula
Calculation methods vary by purpose and subject. No single display precision or rounding rule applies to every web calculator, so we explain our choices and provide the formulas, conditions, and examples for each calculator.
The Percentage Calculator calculates general mathematical ratios. Tasks with their own rules, such as tax calculations or invoicing, may produce different results because of specific requirements for truncation, rounding, or the order of calculations.
If you find a result that appears incorrect, contact us with the calculator and example inputs.
Back to calculatorHeat transfer uses a temperature difference
The Heat Energy Calculator solves Q = mcΔT for heat, mass, specific heat capacity, or temperature change. Mass and specific heat are positive; heat and temperature change are signed. A Fahrenheit difference is scaled by 5/9 without an absolute-temperature offset. Zero temperature change in inverse mass or specific-heat calculations receives an ambiguity or inconsistency explanation.
The constant-specific-heat model excludes phase changes, chemical reactions, heat losses, container heating, and heater efficiency. Units and arithmetic retain exact fractions. Displays round halfway away from zero; output-unit and precision changes do not create another history record.
Ideal gases use absolute pressure and kelvin
The Ideal Gas Calculator solves PV = nRT for one unknown. Pressure, volume, and amount must be positive, and temperature must be above absolute zero. Celsius and Fahrenheit use their absolute-temperature offsets. Gauge pressure is not converted automatically.
The SI gas constant is exactly 8.31446261815324 J/(mol·K). Arithmetic and unit conversion retain exact fractions until display rounding, halfway away from zero. Result-unit and precision changes do not add history. This single-state model excludes real-gas corrections, phase changes, reactions, gas flow, and equipment operating limits.
Dilution conserves the same solute
The Dilution Calculator uses C₁V₁ = C₂V₂ for positive stock concentration, target concentration, and known solution volume. Both concentrations must use compatible molar or mass-per-volume units. A higher target is rejected; equal concentrations require no dilution.
The model assumes no solute in the diluent and no reaction or loss. The estimated diluent volume V₂ − V₁ assumes additive volumes; the target concentration depends on the final solution volume. Exact fractions retain unit conversion and arithmetic until display rounding, halfway away from zero. Result-unit and precision changes do not add history. Percent, ppm, and conversions requiring a molar mass are not inferred.
Monthly weekday lists use exact calendar rules
The Nth Weekday Calculator finds the first through fifth or last occurrence of one weekday in each month, then keeps dates within the inclusive start/end range. Fifth skips a month with only four occurrences; Last chooses the final occurrence. It uses the same proleptic Gregorian years 0001–9999, with exact whole-day arithmetic and no time-zone or holiday adjustments.
A range may touch at most 1,200 calendar months, including partial endpoint months. All checked months appear in the table and CSV, with omission reasons. Copy date list includes matching dates and conditions. The start, end, occurrence, and weekday are saved in recent history and share links; restoring them does not calculate automatically. CSV is a result export, not an input file for restoration.
Shared expenses reconcile in whole cents
The Shared Expense Calculator accepts 2–10 participants and 1–30 expenses in one currency with two decimal places. Each nonnegative expense supports up to 15 integer digits and 2 decimals. Its whole cents are divided equally among the selected participants; remaining cents go to those participants in displayed order, separately for each expense.
Paid minus allocated share gives each person's net balance. Suggested transfers match payers and recipients in participant order until all balances reach zero. Allocations and settlements use exact integers and reconcile to the total; the plan does not guarantee the fewest transfers and does not send money. Refunds, unequal weights, currency conversion, and prior repayments are outside this model.
Shared Expense also supports Load inputs in the five-entry Recent calculations history, Copy link, and JSON Save/Load inputs file (up to 64 KiB). All participant names and order, expense descriptions and amounts, payers, and sharing selections are included. The common 2,048-character link limit applies; longer inputs remain available as a file and through same-tab history. Restoring inputs does not calculate automatically. CSV exports the full results and allocations, not restorable inputs; formula-like text labels are prefixed with an apostrophe.
Date range overlap counts each covered day once
The Date Range Overlap Calculator compares 2–10 named date ranges in the proleptic Gregorian calendar, from 0001 through 9999. Starts are included. By default ends are also included; turning off Include end dates applies an exclusive end to every range. A same-day range covers one day with inclusive ends and zero days with exclusive ends. An end before its start is rejected.
Days common to all ranges are the intersection. Days covered by at least two ranges count each overlapping day once, even when three or more ranges cover it. Total unique days are the union, so a day is never counted more than once in that total. Pairwise overlaps are separate comparisons and must not be added to obtain the unique overlap total. Identical dates entered under different names remain separate ranges. Overlap segments split whenever the participating ranges change; all result dates show the actual first and last covered days, both inclusive, regardless of the input endpoint setting.
All counts use exact whole-day arithmetic without time zones, daylight saving changes, business-day filtering, or holiday adjustments. Names, range order, dates, and the endpoint setting are included in the five-entry recent history, share links, and JSON input files. Restoring fills inputs without calculating automatically. The shared 2,048-character link and 64 KiB input-file limits apply; long conditions can use an input file or same-tab history without dropping ranges. Result copies and CSV contain the conditions and full overlap and pairwise results. CSV is a result export, not a restorable input file; formula-like text labels are prefixed with an apostrophe.
Timesheets add exact minutes before rounding
The Timesheet Calculator accepts 1–14 named shifts. Each row has a start and end clock time, an explicit Same day or Next day choice, and a whole-minute break. The elapsed interval must be between 0 and 24 hours, and a break cannot exceed it. Equal start and end times mean zero elapsed minutes on the same day, or 24 hours when Next day is chosen. The initial and Reset state has two blank shifts, Same day, and zero break minutes.
Elapsed minutes minus break minutes gives each row's net minutes. Totals add the integer minutes before converting to hours; decimal hours are displayed to two places using the site's halfway-away-from-zero rounding. Adding rounded row hours can differ from the displayed total. Rows are independent and all are added, so the tool does not detect overlapping shifts or remove duplicate work. Labels identify rows and are not interpreted as dates.
This is wall-clock arithmetic without dates, time zones, daylight-saving adjustments, payroll rounding, wages, or overtime rules. Enter only breaks you want to subtract. The result is a duration total, not a determination of paid time. For elapsed time across a clock change, supply an independently adjusted duration using the Time Calculator instead.
Shift names and order, clock times, day choices, and break minutes are included in the five-entry recent history, share links, and JSON input files. Restoration fills the form without calculating automatically. The existing 2,048-character link and 64 KiB file limits apply; longer conditions can use a file or same-tab history. Copies and CSV contain the conditions and results. CSV is a result export rather than a restorable input file, and formula-like labels receive a leading apostrophe.
Prorated costs use the actual billing-period days
The Prorated Cost Calculator divides a nonnegative full-period amount by the actual calendar-day count of an explicitly entered billing period, then allocates it to a selected period within those dates. Amounts support up to 15 integer digits and 2 decimal places in one currency. All four dates are required and use proleptic Gregorian years 0001–9999. Starts are always included; by default both period ends are also included. Turning off Include end dates excludes the end in both periods. The billing period must contain at least one day; an end-exclusive same-day selected period contains zero days. Dates outside the billing period are rejected, not silently clipped.
The charge is full-period cents × selected days ÷ billing days, rounded once to whole cents using the site's halfway-away-from-zero rule. The remaining amount is the full-period amount minus that rounded charge, so the two reconcile exactly. The daily rate is displayed to six decimal places and the selected share to two; these rounded display values are not used to calculate the charge.
This model uses actual days, without fixed 30-day months, time-of-day or time-zone adjustments, business-day filtering, taxes, interest, or contract rules. A calculated remaining amount does not establish a refund or credit entitlement. Confirm the applicable billing agreement separately.
The amount, billing dates, selected dates, and end-date choice are included in the five-entry recent history, share links, and JSON input files. Restoration fills inputs without calculating automatically. The shared 2,048-character link and 64 KiB file limits apply. Result copies and CSV include the conditions and results; CSV is not a restorable input file. Initial and Reset inputs are blank with Include end dates selected.
Payment fees use your rate and cent rounding
The Payment Fee Calculator estimates one payment in a currency with two decimal places using a percentage fee and a fixed fee that you supply. Amounts are nonnegative and support up to 15 integer digits and 2 decimal places. The percentage must be from 0 up to, but not including, 100, with at most 10 decimal places. No provider rate or payment method is selected automatically.
The fee is payment amount × percentage ÷ 100 + fixed fee, rounded once to cents using the site's halfway-away-from-zero rule. Net received is the payment amount minus that fee. Integer and exact fractional arithmetic preserve the cent calculation. A fee larger than the payment produces a negative net; the model does not cap the fee. The fixed fee applies once even to a zero payment.
The target-net mode finds the smallest nonnegative whole-cent payment whose net meets the entered target after the same fee rounding. When that payment is above zero, the result also checks the payment one cent lower. This uses the rounded fee rule rather than rounding a continuous algebraic estimate. Rates very close to 100% can produce large required payments; results are not capped at the input amount limit.
This model does not apply fee tiers, minimum or maximum fees, taxes, currency conversions, refunds, cross-border additions, or contract terms. The result does not establish a provider's actual charge or permission to add a fee to a customer's bill. Check the terms and rates that apply to your payment separately.
The initial and Reset state uses Net after fees, blank amount and rate, and a fixed fee of 0.00. Example buttons keep the mode while replacing the numbers. Recent calculations, share links, and JSON input files store the mode, amount, percentage, and fixed fee. Restoration fills the inputs without calculating automatically. The shared 2,048-character link and 64 KiB input-file limits apply. Result copies and CSV include the conditions and results; CSV is not a restorable input file.
Recipe costs use the quantities consumed
The Recipe Cost Calculator multiplies each package price by quantity used ÷ package quantity, sums the ingredient costs, and divides that exact sum by the number of servings. Use one currency with two decimal places throughout. For each ingredient, express the package and used quantities in the same unit. The unit is a label only: the calculator does not convert units, infer ingredient density, or adjust for trimming or cooking loss.
Enter 1–12 ingredients with different names of up to 60 characters and unit labels of up to 20 characters. Package prices are nonnegative, with at most 15 integer digits and 2 decimal places. Quantities accept at most 9 integer digits and 6 decimal places; package quantity must be positive and quantity used may be zero or greater than one package. Use 1–10,000 whole servings. Correctly grouped commas are accepted in prices and quantities. Blank numeric rows are not skipped; complete them or remove them.
Costs are retained as exact fractions of a cent. The total comes from the unrounded ingredient costs, and per-serving cost comes from that unrounded total. Each displayed money amount is rounded independently to 2 places with exact halfway values rounded up. Rounded ingredient rows may not add to the displayed total, and rounded per-serving cost multiplied by servings may differ from that total. Displayed rounded amounts are never reused to calculate the totals.
This is the cost of the quantities used, not the cash required to buy whole packages, a selling price, or complete business cost. Labor, energy, packaging, taxes, spoilage, and other overhead are not added automatically. Enter quantities on a consistent usable or purchased basis and include only the costs you intend to model.
The initial and Reset state has 1 serving and two ingredient rows named Ingredient 1 and Ingredient 2, with unit g and blank prices and quantities. Recent calculations, share links, and JSON input files retain servings, row order, names, units, prices, and both quantities. Restoration fills inputs without calculating automatically. The shared 2,048-character link and 64 KiB input-file limits apply; longer conditions can use a JSON file or same-tab history restoration. Result copies and CSV contain the conditions and results; CSV is not a restorable input file.
Last updated: November 3, 2026